iRB5-100 Holographic Intelligent Miniature Circuit Breaker
Applicable to low-voltage distribution in residential, commercial, industrial, and other fields.
Applicable to low-voltage distribution in residential, commercial, industrial, and other fields.
The functions of intelligent breaker include electrical protection, monitoring, fault identification, and load management, so as to enhance the electrical safety, enable precise energy efficiency management, and monitor power quality. The integrated design has changed the form of splicing modules and reduced the product size.
FEATURES AND BENEFITS
Safety protection
Short circuit, overload, overvoltage, undervoltage, phase loss,Neutral Disconnection Protection, and other protections
Arc fault protection
Electricity management
Timed opening and closing, automatic reclosing, local + remote control
Health assessment, lifespan prediction, fault prediction
Load identification, operation modeling
Smart monitoring
Full parameter monitoring, temperature monitoring, fault identification and monitoring Power flicker monitoring
Fault Recording function
Technical Characteristics
|
Product Series |
iRB5-100H |
|
Standards met |
IEC/EN 60947-2, GB/T 14048.2, CQC1148 |
|
Product certification |
CCC,CQC,TUV,CE,CB |
|
Electrical Characteristics |
|
|
Number of poles |
1P,2P,3P,4P |
|
Rated current In (A) |
6,10,16,20,25,32,40,50,63,80,100* |
|
Rated voltage Ue (V) |
230/400V |
|
Rated insulation voltage Ui (V) |
500 |
|
Rated operating frequency f (Hz) |
50/60 |
|
Rated impulse withstand voltage U imp (kV) |
4 |
|
Rated short-circuit capacity Icn |
10kA |
|
Rated ultimate short-circuit breaking capacity lcu |
10kA |
|
Rated operational short-circuit breaking capacity lcs |
7.5kA |
|
Current limit grade |
Level 3 |
|
Instantaneous break characteristic |
C,D |
|
Mechanical Characteristics |
||
|
Mechanical lifespan |
20,000 Times |
|
|
Electrical lifespan (In) |
10,000 Times |
|
|
Protection level |
Circuit breaker body |
IP20 |
|
Installed in the distribution box |
IP40 |
|
|
Other Characteristics |
||
|
Pollution level |
Ⅱ |
|
|
Operating temperature |
-40°C~+85°C |
|
|
Storage temperature |
-40°C~+85°C |
|
|
Wiring method |
Top entry, bottom exit |
|
|
Installation direction |
Vertical installation |
|
|
Resistance to damp and heat |
Class 2 (temperature 55°C,relative humidity 95%) |
|
|
Communication interface |
RS485,Bluetooth |
|
|
Communication protocol |
Modbus,IEC60870-5-101 |
|
|
Basic & Advanced Protection |
● |
|
|
Full parameter & temperature monitoring |
● |
|
|
Fault identification and recording |
● |
|
|
Load management |
● |
|
|
Health monitoring |
● |
|
|
Event and alarm records |
● |
|
|
Arc fault monitoring and protection |
○ |
|
|
Advanced functions |
○ |
|
*: When the rated current is 100A, currently only products with a breaking capacity of 6kA are available. The breaking capacity code is N. Except for the breaking capacity Ics=Icu=6kA, other parameters are the same as those of products with a breaking capacity of 10kA.
|
Wiring |
||||||
|
Current rating |
Screw |
Rated torque (Nm) |
Maximum torque (Nm) |
National Standard Rated Torque (Nm) |
Maximum wiring capacity (mm²) |
|
|
Hard wire |
Soft wire |
|||||
|
6-100A |
M6 |
3.5 |
8 |
3 |
35 |
25 |
|
Reference weight (g) |
|||
|
1P |
2P |
3P |
4P |
|
212.7 |
350.1 |
494.5 |
632.9 |